Calculator, estimate only

Arm and cartridge resonance

A tonearm and cartridge act together as a mass on a spring: the moving mass is the arm's effective mass plus the cartridge and its screws, and the spring is the stylus suspension's compliance. This page works out the frequency at which that pair resonates, from figures you copy off the makers' published specifications.

Resonance estimate

Type the figures from the makers' published sheets. Nothing is looked up or stored.

From the tonearm or turntable maker's specification. Unit: g.

From the cartridge maker's specification. Unit: g.

Screws, nuts and any spacer. Enter 0 if none or if already counted. Unit: g.

As the cartridge maker quotes it. 1 µm/mN is the same as 10⁻⁶ cm/dyne. Unit: µm/mN.

The frequency the maker states for that compliance figure. Shown with the result; not used in the sum. Unit: Hz.

Enter the four figures, then choose Estimate resonance.

How the estimate is worked out

f = 1000 ÷ (2π × √(M × C))

f is the resonance in hertz. M is the total moving mass in grams: tonearm effective mass + cartridge mass + mounting hardware mass. C is the cartridge's dynamic compliance in µm/mN, the same number as a figure in 10⁻⁶ cm/dyne.

This is the standard mass and spring formula f = 1 ÷ (2π√(mC)) with m in kilograms and C in metres per newton. Writing the mass in grams (×10⁻³) and the compliance in µm/mN (×10⁻³ m/N) puts a factor of 10⁻⁶ under the square root, which comes out as the 1000 on top.

Worked example: 9 g of arm, 6 g of cartridge and no extra hardware give M = 15 g. With C = 15 µm/mN, √(15 × 15) = 15, and f = 1000 ÷ (2π × 15), about 10.6 Hz.

What the estimate assumes

  • All three masses are in grams and add straight together. The arm figure must be the maker's effective mass, not the arm's weight on a scale.
  • The compliance is used exactly as you type it. Makers state compliance at a test frequency, often 10 Hz or 100 Hz, and figures measured at different test frequencies are not interchangeable. The tool shows the frequency you enter beside the result and does not convert between them.
  • If a maker gives separate lateral and vertical compliance, the result applies to the figure you typed.
  • It ignores damping, bearing friction and the arm's own flexing, so the real resonance can sit away from this figure. Treat the result as an estimate.
  • No target range is built in. Compare the result with the range your cartridge maker publishes.

Units

The conversions above use SI definitions (1 dyne = 10⁻⁵ newton), as set out in the NIST Guide to the SI (Special Publication 811), National Institute of Standards and Technology.